Rentals: Combustors
T-Rush Enclosed
Vapour Combustor
-
Stock Number CRC-C-005
-
Qty 1
-
Condition: New
-
Location: Sundre
Features & Specifications:
-
550,000 scf/d with 1000btu/scf gas
-
Air Intake Flame arrestors
-
4" Main
-
2-Skin Temp Thermocouple
-
Exhaust Temp Thermocouple
-
ACL-CSC 400 BMS
-
B149.3 compliant pilot gas train
-
Min 2oz of waste gas pressure
-
Power Requirements: 24 VDC, Optional Solar
-
Pilot fuel requirements: Natural Gas or Propane
-
Skid Mounted
-
12' Diameter
-
20' Tall
CRC-BB-400-4
-
Stock Number: CRC-C-004
-
Qty 1
-
Condition: New
-
Location: Sundre
Features & Specifications:
-
Enclosed vapour combustor with 78,000 SCFD capacity @ 2oz
-
Carbon steel outer fire chamber lined with 1" thick refractory for enclosed flame
-
Air intake flame arrestors
-
ACL CSC400 Burner Management System
-
Dual Pilot Assembly
-
Knock-out accumulator equipped with level gauge and level switch wired into BMS, with 2" NPT pumpout port
-
2" inline flame arrestor
-
2" y-strainer
-
2" FPS D90 Ball Valve with proof of closure limit switch and visual indication pre-wired with BMS
-
Solar Powered
-
Nitrogen tank for instrument air BB-400 comes pre-wired and pre-plumbed for quick and easy installation
-
Free-standing skid mounted for easy mobility
-
3" #150 lbs flange hook-up
-
Ability to run multiple units in parallel

BGR Cube 500
-
Stock Number: CRC-C500-001-015
-
Qty 15
-
Condition: New
-
Location: Sundre
Features & Specifications:
-
Destruction removal efficiency greater than 99.9% and meets the requirements of EPA NSPS 40 CFR 60 Subpart 0000 and AER Directive 60 & Saskatchewan S 20
-
Reduced spacing 10m from storage tanks or wellheads
-
ACL-CSC 400 BMS
-
-B149.3 Approved Fuel Train
-
Air intake flame arrestors
-
Low skin temperature
-
Low exhaust temperature
-
No visible flame
-
Direct spark ignition or continuous pilot
-
5′ x 5′ x 10′ high free standing
-
Low pressure burner volume up to 17,500scf/d or 500 m3/d
-
Excellent turndown ratio 100:1

BGR Cube 1000
-
Stock Number: CRC-C1000-001-015
-
Qty 15
-
Condition: New
-
Location: Sundre
Features & Specifications:
-
Destruction removal efficiency greater than 99.9% and meets the requirements of EPA NSPS 40 CFR 60 Subpart 0000 and AER Directive 60 & Saskatchewan S 20
-
Reduced spacing 10m from storage tanks or wellheads
-
ACL-CSC 400 BMS
-
B149.3 Approved Fuel Train
-
Air intake flame arrestors
-
Low skin temperature
-
Low exhaust temperature
-
No visible flame
-
Direct spark ignition or continuous pilot
-
5′ x 5′ x 10′ high free standing
-
Low pressure burner volume up to 35,000scf/d or 1000 m3/d
-
Excellent turndown ratio 100:1
-
Power Requirements: 12 or 24 vdc
-
Solar option

BGR-36 LP Combustor
-
Stock Number: CRC-C-003-04
-
Qty: 2
-
Location: Sundre
Features & Specifications:
-
Destruction removal efficiency greater than 99.9% and meets the requirements of EPA NSPS 40 CFR 60 Subpart OOOO, AER Directive 60, and Saskatchewan S-20
-
36” x 24’ high-free standing
-
Stainless steel fire tube
-
May be operated with or without continuous pilot
-
Air intake flame arrestor for reduced spacing or teardrop locations
-
Main low pressure burner volume up to 100,000 scf/d or 2831 m3/d
-
Operating pressures as low as 0.09 psi or 1.5 oz/in2
-
Able to handle intermittent flows easily
-
Flame containment mesh at air inlets for operator safety
-
No visible flame
-
Excellent turndown ratio
-
Heat shield for operator safety
-
In-line flame arrestor required
-
Free Standing Base
-
12/24 VDC Required
-
Solar Option Available
-
Propane or Natural Gas Required for Pilot

BGR-18 LP Combustor
-
Stock Number: CRC-C-01
-
Location Sundre
Features & Specifications:
-
Destruction removal efficiency greater than 99.9% and meets the requirements of EPA NSPS 40 CFR 60 Subpart OOOO, AER Directive 60, and Saskatchewan S-20
-
18” x 24’ high-free standing
-
Stainless steel fire tube
-
May be operated with or without continuous pilot
-
Air intake flame arrestor for reduced spacing or teardrop locations
-
Main low pressure burner volume up to 20,000 scf/d or 566 m3/d
-
Operating pressures as low as 0.09 psi or 1.5 oz/in2
-
Able to handle intermittent flows easily
-
Flame containment mesh at air inlets for operator safety
-
No visible flame
-
Excellent turndown ratio
-
Heat shield for operator’s safety
-
In-line flame arrestor required
-
Free Standing Base
-
12/24 VDC Required
-
Solar Option Available
-
Propane or Natural Gas Required for Pilot

BGR-24 HPLP Trailer
Mounted Combustor
-
Stock Number: CRC-PC-001
-
Location Sundre
Features & Specifications:
-
Patented high volume combustion device
-
1,745,000 scf/d flow rate capacity
-
Meets or exceeds the U.S. EPA NSPS Subpart OOOO (“Quad O”), AER Directive 60 and Saskatchewan S-20 Regulations
-
High pressure destruction efficiency greater than 98%
-
Low pressure destruction efficiency greater than 99.9%
-
LP operating pressures from 0.09 psi (1.5 oz/in2) to 15 psi
-
HP operating pressures from 0 psi to 120 psi
-
24″ x 24′ stainless steel fire tube
-
May be operated with or without continuous pilot
-
Excellent turndown ratio
-
Heat shield for operator’s safety
-
2 5/16 Ball Hitch
-
12 VDC Power Pack
-
Power Requirements: 12/24 VDC
-
Propane or Natural Gas Pilot